Alfa Romeo Selespeed system
    Back to INDEX    
     
         
 

FAULTS and TROBLESHOOTINGS

 

The engine has switched off

   
 
Symptom/conditions: The engine has switched off
  • * While the car is stopping
    * While the car is starting
    * With the car stationary

 

   
 
Step Operations Test results
 
0 Check oil level All OK Problems found Intervention
 
  Check oil level as shown in Procedure 2 Go to step 1 Level other than max Do Procedure 3
 
1 Check oil pressure All OK Problems found Intervention
 
  Check oil pressure as shown in Procedure 4 Go to step 2 Press < 40 bar Do Procedure 5
 
2 Check ECU errors All OK Problems found Intervention
 
  Check there are no errors in the control unit. In particular:
* Clutch sensor error
* Clutch solenoid valve current error
* Load relay error
* Odd gears engagement ( Vbat short circuit)
* Even gears engagement error (Vbat short circuit)
Go to step 4 Presence of one or more errors included in the list Go to step 3
 
3 Check problems found All OK Problems found Intervention
 
  Check problems according to Procedure 17 End of procedure The problem persists Go to step 4
 
4 Check that the clutch does not drag All OK Problems found Intervention
 
  Check that the clutch does not drag following Procedure 14 Go to step 6 The clutch drags Overhaul the clutch/flywheel kit and replace and broken components. Go to step 5
 
5 After intervention on the clutch kit All OK Problems found Intervention
 
  Check that the problem is no longer present. End of procedure The problem persists Go to step 6
 
6 The problem persists All OK Problems found Intervention
 
  Check there are no errors or problems on other systems installed don the car Go to step 7 Faults are found Proceed following the indications of Examiner
 
7 The problem persists All OK Problems found Intervention
 
        Contact technical assistance for additional information on the problem