Check that the
bleeder screw (under the battery rack) is tightened to a torque of
0.35 daNm + 0.05 daNm, otherwise, even if the pump is running, the
oil pressure will never reach the required value.
1. Set the ignition key to MAR.
2. Connect the Examiner diagnostics tool.
3. With the electric pump off, the pressure should be between 40 and
55 bar at environment temperature.